|
|
Dosimetry Study of High Dose Rate Flattening Filter-Free Radiation on the Protection of Lumbosacral Spine and Pelvic Bone Marrow |
Xiufeng Cong1, Jun Chen1, Xiaoting Zhang1, Zaiming Lu2* |
1. Department of Clinical Oncology, Shengjing Hospital of China Medical University, Shenyang 110042 2. Liaoning China (Xiufeng Cong, Jun Chen, Xiaoting Zhang)Correspondence: Zaiming Lu, Department of radiology, Shengjing Hospital of China Medical University. |
|
|
Abstract Objective This study aimed to analyze the dosimetric parameters of volumetric modulated arc therapy (VMAT) and dynamic multileaf collimator (DMLC) plans with lumbosacral spine (LS) and pelvic bone marrow (PBM) sparing in the flattening filter-free (FFF) model.Methods Thirty patients with cervical cancer were selected for analysis. For each patient, four plans with different strategies were generated: VMAT_FF, VMAT_FFF, DMLC_FF, and DMLC_FFF. Dose volumes for organs at risk, conformity index, heterogeneity index (HI), and total number of machine unit (MU) were compared by paired t-test.Result Compared with plans in the FF model, the irradiated dose to LS significantly decreased both VMAT_FFF and DMLC_FFF plans in the FFF model while the MU increased. The mean dose of LS decreased by 107.2 cGy (P<0.05) in the VMAT_FFF plan. In comparison with the VMAT plans in both models of FF and FFF, the DMLC plans reduced the dose volume of 10 Gy by 5.9% (P<0.05), and the mean dose of LS was 189.6-293.1 cGy. The PBM volume receiving 40 Gy showed a decrease of 0.5%-1.1% (P<0.05) as well. The HI increased in the VMAT plans by approximately 0.053 and 0.039.Conclusion The DMLC plans exhibited the best sparing of the PBM and LS in both FF and FFF models and increased the HI. The plans in the FFF model could limit the volume dose of LS but increase the MU.
|
|
|
|
|
[1] Folkert M R, Shih K K, Abu-Rustum N R, et al.Postoperative pelvic intensity-modulated radiotherapy and concurrent chemotherapy in intermediate- and high-risk cervical cancer[J]. Gynecol Oncol, 2013, 128(2):288-293. [2] Nicholas S, Chen L, Choflet A, et al.Pelvic Radiation and Normal Tissue Toxicity[J]. Semin Radiat Oncol, 2017, 27(4):358-369. [3] Mell L K, Sirak I, Wei L, et al.Bone Marrow-sparing Intensity Modulated Radiation Therapy With Concurrent Cisplatin For Stage IB-IVA Cervical Cancer: An International Multicenter Phase II Clinical Trial (INTERTECC-2)[J]. Int J Radiat Oncol Biol Phys, 2017, 97(3):536-545. [4] Wan J, Liu K, Li K, et al.Can dosimetric parameters predict acute hematologic toxicity in rectal cancer patients treated with intensity-modulated pelvic radiotherapy?[J]. Radiat Oncol, 2015, 10:162. [5] Fischer-Valuck B W, Rao Y J, Michalski J M. Intensity-modulated radiotherapy for prostate cancer[J]. Transl Androl Urol, 2018, 7(3):297-307. [6] Han N, Lyu X, Li G, et al.Impact of adaptive intensity-modulated radiotherapy on the neutrophil-to-lymphocyte ratio in patients with nasopharyngeal carcinoma[J]. Radiation Oncology, 2019, 14(1). [7] Scobioala S, Kittel C, Elsayad K, et al.A treatment planning study comparing IMRT techniques and cyber knife for stereotactic body radiotherapy of low-risk prostate carcinoma[J]. Radiation Oncology, 2019, 14(1). [8] Hoffman D, Dragojevi? I, Hoisak J, et al.Lung Stereotactic Body Radiation Therapy (SBRT) dose gradient and PTV volume: a retrospective multi-center analysis[J]. Radiation Oncology, 2019, 14(1). [9] Bao Z, Wang D, Chen S, et al.Optimal dose limitation strategy for bone marrow sparing in intensity-modulated radiotherapy of cervical cancer[J]. Radiation Oncology, 2019, 14(1). [10] Stevens M, Lobb E C, Yenice K M. Validation of MLC-based linac radiosurgery for trigeminal neuralgia[J]. J Appl Clin Med Phys, 2018, 19(4):214-221. [11] Georg D, Kn??s T, Mcclean B. Current status and future perspective of flattening filter free photon beamsa[J]. Medical Physics, 2011, 38(3):1280-1293. [12] Huang Y, Siochi R A, Bayouth J E. Dosimetric properties of a beam quality-matched 6 MV unflattened photon beam[J]. J Appl Clin Med Phys, 2012, 13(4):3701. [13] Zhang W, Lin Z, Yang Z, et al.Evaluation of the dosimetric impact of applying flattening filter-free beams in intensity-modulated radiotherapy for early-stage upper thoracic carcinoma of oesophagus[J]. J Med Radiat Sci, 2015, 62(2):108-113. [14] Unkelbach J, Bortfeld T, Craft D, et al.Optimization approaches to volumetric modulated arc therapy planning[J]. Med Phys, 2015, 42(3):1367-1377. [15] Potrebko P S, Keller A, All S, et al.GammaKnife versus VMAT radiosurgery plan quality for many brain metastases[J]. J Appl Clin Med Phys, 2018, 19(6):159-165. [16] Lyu Q, O'Connor D, Ruan D, et al.VMAT optimization with dynamic collimator rotation[J]. Med Phys, 2018, 45(6):2399-2410. [17] Osborn J. Is VMAT beneficial for patients undergoing radiotherapy to the head and neck?[J]. Radiography (Lond), 2017, 23(1):73-76. [18] Molazadeh M, Zeinali A, Robatjazi M, et al.Dosimetric characteristics of LinaTech DMLC H multi leaf collimator: Monte Carlo simulation and experimental study[J]. J Appl Clin Med Phys, 2017, 18(2):113-124. [19] Akino Y, Mizuno H, Isono M, et al.Small‐field dosimetry of TrueBeamTM flattened and flattening filter‐free beams: A multi‐institutional analysis[J]. Journal of Applied Clinical Medical Physics, 2020, 21(1):78-87. [20] Martin-Martin G, Aguilar P B, Barbés B, et al. Assessment of ion recombination correction and polarity effects for specific ionization chambers in flattening-filter-free photon beams[J]. Physica Medica, 2019, 67:176-184. [21] Garcia P E, Lopez P, Torija M, et al.Analysis of PLA Geometric Properties Processed by FFF Additive Manufacturing: Effects of Process Parameters and Plate-Extruder Precision Motion[J]. Polymers (Basel), 2019, 11(10). [22] Khan M, Heilemann G, Lechner W, et al.Basic Properties of a New Polymer Gel for 3D-Dosimetry at High Dose-Rates Typical for FFF Irradiation Based on Dithiothreitol and Methacrylic Acid (MAGADIT): Sensitivity, Range, Reproducibility, Accuracy, Dose Rate Effect and Impact of Oxygen Scavenger[J]. Polymers (Basel), 2019, 11(10). [23] Hyun M A, Miller J R, Micka J A, et al.Ion recombination and polarity corrections for small-volume ionization chambers in high-dose-rate, flattening-filter-free pulsed photon beams[J]. Medical Physics, 2017, 44(2):618-627. [24] Abdulle A, Chow J. Contrast Enhancement for Portal Imaging in Nanoparticle-Enhanced Radiotherapy: A Monte Carlo Phantom Evaluation Using Flattening-Filter-Free Photon Beams[J]. Nanomaterials (Basel), 2019, 9(7). [25] Wang L, Ding G X. Estimating the uncertainty of calculated out-of-field organ dose from a commercial treatment planning system[J]. J Appl Clin Med Phys, 2018, 19(4):319-324. [26] Narayanasamy G, Saenz D, Cruz W, et al.Commissioning an Elekta Versa HD linear accelerator[J]. J Appl Clin Med Phys, 2016, 17(1):179-191. [27] Saenz D L, Narayanasamy G, Cruz W, et al.Pinnacle3 modeling and end-to-end dosimetric testing of a Versa HD linear accelerator with the Agility head and flattening filter-free modes[J]. J Appl Clin Med Phys, 2016, 17(1):192-206. [28] Duan J, Meng X, Liu T, et al.Capability of leaf interdigitation with different inverse planning strategies in Monaco: an investigation of representative tumour sites[J]. Radiat Oncol, 2016, 11:82. [29] Narayanasamy G, Saenz D L, Defoor D, et al.Dosimetric validation of Monaco treatment planning system on an Elekta VersaHD linear accelerator[J]. J Appl Clin Med Phys, 2017, 18(6):123-129. [30] Meshram M N, Pramanik S, Ranjith C P, et al.Dosimetric properties of equivalent-quality flattening filter-free (FFF) and flattened photon beams of Versa HD linear accelerator[J]. J Appl Clin Med Phys, 2016, 17(3):358-370. [31] Saenz D L, Li Y, Rasmussen K, et al.Dosimetric and localization accuracy of Elekta high definition dynamic radiosurgery[J]. Physica Medica, 2018, 54:146-151. [32] Bratengeier K, Herzog B, Wegener S, et al.Finer leaf resolution and steeper beam edges using a virtual isocentre in concurrence to PTV-shaped collimators in standard distance–a planning study[J]. Radiation Oncology, 2017, 12(1). [33] Ma C, Chen M, Long T, et al.Flattening filter free in intensity‐modulated radiotherapy (IMRT) – Theoretical modeling with delivery efficiency analysis[J]. Medical Physics, 2019, 46(1):34-44. [34] Güng?r G, Demir M, Ayd?n G, et al.Improvement of conformal arc plans by using deformable margin delineation method for stereotactic lung radiotherapy[J]. Journal of Applied Clinical Medical Physics, 2017, 19(1):184-193. [35] Chung J B, Kim J S, Eom K Y, et al.Comparison of VMAT-SABR treatment plans with flattening filter (FF) and flattening filter-free (FFF) beam for localized prostate cancer[J]. J Appl Clin Med Phys, 2015, 16(6):302-313. [36] Xiao Y, Kry S F, Popple R, et al.Flattening filter‐free accelerators: a report from the AAPM Therapy Emerging Technology Assessment Work Group[J]. Journal of Applied Clinical Medical Physics, 2015, 16(3):12-29. [37] Takahashi W, Nawa K, Haga A, et al.Acceptable fetal dose using flattening filter-free volumetric arc therapy (FFF VMAT) in postoperative chemoradiotherapy of tongue cancer during pregnancy[J]. Clin Transl Radiat Oncol, 2020, 20:9-12. [38] Sangaiah A, Ganesh K M, Ramalingam K, et al.Dosimetric Validation of Volumetric Modulated Arc Therapy (VMAT) Using AAPM TG-119 Benchmark Plans in an Upgraded CLINAC 2100CD for Flattening Filter Free (FFF) Photon Beams[J]. Asian Pac J Cancer Prev, 2017, 18(11):2965-2970. [39] Lu J, Lin P, Huang B. Calculating the individualized fraction regime in stereotactic body radiotherapy for non-small cell lung cancer based on uncomplicated tumor control probability function[J]. Radiation Oncology, 2019, 14(1). [40] Liu H, Sintay B, Pearman K, et al.Comparison of the progressive resolution optimizer and photon optimizer in VMAT optimization for stereotactic treatments[J]. J Appl Clin Med Phys, 2018, 19(4):155-162. [41] Chapman C H, Mcguinness C, Gottschalk A R, et al.Influence of respiratory motion management technique on radiation pneumonitis risk with robotic stereotactic body radiation therapy[J]. J Appl Clin Med Phys, 2018, 19(4):48-57. [42] Hrbacek J, Lang S, Graydon S N, et al.Dosimetric comparison of flattened and unflattened beams for stereotactic ablative radiotherapy of stage I non-small cell lung cancer[J]. Medical Physics, 2014, 41(3):31709. [43] Oh S, Lewis B, Watson A, et al.The effect of beam interruption during FFF-VMAT plans for SBRT[J]. Australas Phys Eng Sci Med, 2017, 40(4):931-938. [44] Kawahara D, Ozawa S, Kimura T, et al.Photon and electron backscatter dose and energy spectrum analysis around Lipiodol using flattened and unflattened beams[J]. J Appl Clin Med Phys, 2019, 20(6):178-183. [45] Kawahara D, Ozawa S, Saito A, et al.Effect of secondary electron generation on dose enhancement in Lipiodol with and without a flattening filter[J]. J Appl Clin Med Phys, 2018, 19(2):211-217. [46] Cashmore J. Surface dose variations in 6 and 10 MV flattened and flattening filter-free (FFF) photon beams[J]. J Appl Clin Med Phys, 2016, 17(5):293-307. [47] Cashmore J. Surface dose variations in 6 and 10 MV flattened and flattening filter-free (FFF) photon beams[J]. J Appl Clin Med Phys, 2016, 17(5):293-307. [48] Edvardsson A, Nordstrom F, Ceberg C, et al.Motion induced interplay effects for VMAT radiotherapy[J]. Phys Med Biol, 2018, 63(8):85012. [49] Vassiliev O N, Kry S F, Wang H C, et al.Radiotherapy of lung cancers: FFF beams improve dose coverage at tumor periphery compromised by electronic disequilibrium[J]. Physics in Medicine & Biology, 2018, 63(19):195007. [50] Pokhrel D, Halfman M, Sanford L. FFF-VMAT for SBRT of lung lesions: Improves dose coverage at tumor-lung interface compared to flattened beams[J]. J Appl Clin Med Phys, 2020, 21(1):26-35. [51] Sun W Z, Chen L, Yang X, et al.Comparison of treatment plan quality of VMAT for esophageal carcinoma with: flattening filter beam versus flattening filter free beam[J]. J Cancer, 2018, 9(18):3263-3268. [52] Kubo K, Monzen H, Tamura M, et al.Minimizing dose variation from the interplay effect in stereotactic radiation therapy using volumetric modulated arc therapy for lung cancer[J]. Journal of Applied Clinical Medical Physics, 2018, 19(2):121-127. |
|
|
|